TY - JOUR
T1 - A flow system for the spectrophotometric determination of lead in different types of waters using ion-exchange for pre-concentration and elimination of interferences
AU - Mesquita, Raquel B. R.
AU - Fernandes, Sílvia M. V.
AU - Rangel, António O. S. S.
PY - 2004/2/6
Y1 - 2004/2/6
N2 - A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex 100) operating in a sequential injection mode. To improve the mixture of sample and reagents, a flow injection approach was adopted for the colorimetric determination. This way a hybrid flow system, involving both sequential and flow injection concepts was designed. Another feature of the proposed system is the efficient elimination of major interferent species, such as cadmium and copper. The elimination of cadmium interference is obtained by complexing Cd2+ with chloride and retaining the formed negatively charged complexes in an anionic resin, AG1 X-8. As for copper, with the presence of both ionic resins as well as the conditions for cadmium elimination, it no longer acts as an interferent. Different ranges of lead concentration (50-300 and 300-1000 μg l-1) can be determined with minor changes in the controlling software, useful for application to both natural and waste waters. Therefore, a detection limit of 25 μg l-1 was achieved. Repeatability was evaluated from 10 consecutive determinations being the results better than 4%. The recoveries of lead spikes added to the samples ranged from 93 to 102%. The sampling frequency was 17 and 24 determinations per hour, for 50-300 and 300-1000 μg l -1 ranges, respectively.
AB - A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex 100) operating in a sequential injection mode. To improve the mixture of sample and reagents, a flow injection approach was adopted for the colorimetric determination. This way a hybrid flow system, involving both sequential and flow injection concepts was designed. Another feature of the proposed system is the efficient elimination of major interferent species, such as cadmium and copper. The elimination of cadmium interference is obtained by complexing Cd2+ with chloride and retaining the formed negatively charged complexes in an anionic resin, AG1 X-8. As for copper, with the presence of both ionic resins as well as the conditions for cadmium elimination, it no longer acts as an interferent. Different ranges of lead concentration (50-300 and 300-1000 μg l-1) can be determined with minor changes in the controlling software, useful for application to both natural and waste waters. Therefore, a detection limit of 25 μg l-1 was achieved. Repeatability was evaluated from 10 consecutive determinations being the results better than 4%. The recoveries of lead spikes added to the samples ranged from 93 to 102%. The sampling frequency was 17 and 24 determinations per hour, for 50-300 and 300-1000 μg l -1 ranges, respectively.
KW - Flow system
KW - Ion-exchange
KW - Lead determination
KW - Spectrophotometry
KW - Waters
UR - http://www.scopus.com/inward/record.url?scp=0348226457&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2003.08.009
DO - 10.1016/j.talanta.2003.08.009
M3 - Article
C2 - 18969308
AN - SCOPUS:0348226457
SN - 0039-9140
VL - 62
SP - 395
EP - 401
JO - Talanta
JF - Talanta
IS - 2
ER -