Bleb morphology of glaucoma drainage devices on magnetic resonance imaging

Rafael Correia Barão*, David Berhanu, Diogo Bernardo Matos, André Diogo Barata, Rita Sousa, Luís Abegão Pinto

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Purpose: To evaluate bleb morphology features of different glaucoma drainage devices (GDD) using magnetic resonance imaging (MRI). Materials and Methods: Prospective cohort study of GDD and bleb morphology in consecutive glaucoma patients implanted with Ahmed Glaucoma Valve (AGV), Paul Glaucoma Implant (PGI), Baerveldt Glaucoma Implant (BGI) and Ahmed ClearPath (ACP) devices. Thirty-six eyes from 30 consecutive patients underwent standardized GDD implantation followed by MRI at least 1 month after surgery. Main outcomes included bleb volume and endplate position relative to the optic nerve. Secondary outcomes included intraocular pressure (IOP), medication and surgical complications during a 12-month follow-up. Results: Seven eyes were implanted with the AGV (19%), 5 with BGI (14%), 16 with PGI (44%) and 8 with ACP (22%). MRI scans were obtained 85 ± 66 days after surgery. Mean total bleb volume was 563 ± 390 mm3. This bleb volume was inversely correlated with early post-operative IOP (day 7; rs = −0.3326, p = 0.0475) but positively correlated with IOP at 12 months (rs = 0.3592, p = 0.0341). No significant difference in total bleb volume was found between GDD types (p = 0.1223). A double-layered bleb was observed in 34 eyes (94%). The inferior bleb volume was significantly larger in PGI devices versus other GDD types (380 ± 205 vs. 193 ± 161 mm3; p = 0.0043). Distance from the endplate to the optic nerve was 9.5 ± 4.0 mm, similar across GDDs (p = 0.2519). Conclusions: Double-layered blebs are a common finding with GDDs. Bleb volume showed different correlations with IOP at distinct timepoints and the PGI device formed larger blebs. A standardized GDD implantation technique ensures a safe distance from the GDD endplate to the optic nerve.

Original languageEnglish
Pages (from-to)789–796
Number of pages8
JournalActa Ophthalmologica
Volume101
Issue number7
DOIs
Publication statusPublished - Nov 2023
Externally publishedYes

Keywords

  • Aqueous shunt
  • Glaucoma
  • Glaucoma surgery
  • Long tube
  • Magnetic resonance imaging
  • Orbit

Fingerprint

Dive into the research topics of 'Bleb morphology of glaucoma drainage devices on magnetic resonance imaging'. Together they form a unique fingerprint.

Cite this