TY - JOUR
T1 - Disposable microfluidic paper-based device for on-site quantification of urinary creatinine
AU - Melo, Maria M. P.
AU - Machado, Ana
AU - Rangel, António O. S. S.
AU - Mesquita, Raquel B. R.
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/6/29
Y1 - 2023/6/29
N2 - In this work, a new microfluidic paper-based analytical device (µPAD) was developed for on-hand creatinine quantification in urine samples. When compared to conventional methods, this innovative paper device is more accessible and portable, it provides low-cost analysis (cost of consumables of 40 cents), and it is applicable to non-invasive biological fluids. Furthermore, the paper-based approach is used within an environmentally friendly assembly with no need for wax printing and small amounts of reagents resulting in low waste production and easy disposal by incineration. Its assembly method includes cutting paper discs arranged into several reading units within a plastic pouch, enabling effective creatinine quantification with accuracy based on a vertical flow approach. The method is based on the colourimetric reaction between creatinine and alkaline picric acid, where the solution colour changes from yellow to orange/red. Under optimal conditions, the developed method allowed creatinine quantification in the dynamic range of 2.20–35.0 mg/dL, with a limit of detection (LOD) of 0.66 mg/dL and a limit of quantification (LOQ) of 2.20 mg/dL. The colour intensity developed was processed in ImageJ software, based on digital image scanning, performed in 20 min (up to 4 h) after the sample insertion. The device is stable for up to one week when stored in a vacuum at 4 °C. The method was validated by comparing the results with a batch-wise procedure, where there were no statistically significant differences between both methods.
AB - In this work, a new microfluidic paper-based analytical device (µPAD) was developed for on-hand creatinine quantification in urine samples. When compared to conventional methods, this innovative paper device is more accessible and portable, it provides low-cost analysis (cost of consumables of 40 cents), and it is applicable to non-invasive biological fluids. Furthermore, the paper-based approach is used within an environmentally friendly assembly with no need for wax printing and small amounts of reagents resulting in low waste production and easy disposal by incineration. Its assembly method includes cutting paper discs arranged into several reading units within a plastic pouch, enabling effective creatinine quantification with accuracy based on a vertical flow approach. The method is based on the colourimetric reaction between creatinine and alkaline picric acid, where the solution colour changes from yellow to orange/red. Under optimal conditions, the developed method allowed creatinine quantification in the dynamic range of 2.20–35.0 mg/dL, with a limit of detection (LOD) of 0.66 mg/dL and a limit of quantification (LOQ) of 2.20 mg/dL. The colour intensity developed was processed in ImageJ software, based on digital image scanning, performed in 20 min (up to 4 h) after the sample insertion. The device is stable for up to one week when stored in a vacuum at 4 °C. The method was validated by comparing the results with a batch-wise procedure, where there were no statistically significant differences between both methods.
KW - Creatinine determination
KW - Jaffe reaction
KW - Real-time analysis
KW - Urine samples
KW - µPAD
UR - http://www.scopus.com/inward/record.url?scp=85166290857&partnerID=8YFLogxK
U2 - 10.3390/chemosensors11070368
DO - 10.3390/chemosensors11070368
M3 - Article
AN - SCOPUS:85166290857
SN - 2227-9040
VL - 11
JO - Chemosensors
JF - Chemosensors
IS - 7
M1 - 368
ER -