TY - JOUR
T1 - Locator® attachment system for implant overdentures
T2 - a systematic review
AU - Miler, Artur Miguel Quaresma Pereira
AU - Correia, André Ricardo Maia
AU - Rocha, José Mário de Castro
AU - Campos, José Carlos Reis
AU - Silva, Maria Helena Guimarães Figueiral da
N1 - Copyright:
This record is sourced from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
PY - 2017
Y1 - 2017
N2 - OBJECTIVE: To evaluate the success rate, complications, maintenance and patient satisfaction with implant-supported overdentures with the Locator® system, by means of a systematic review. MATERIALS AND METHODS: PICO approach was used to formulate the clinical question. Research was conducted in primary (PubMed® and B-On®) and secondary (Cochrane®) information sources using different logical combination strategies of text words and MESH terms. Articles were selected according to research theme and scientific level evidence. RESULTS: 55 articles were found. After reading the title and summary, and evaluating the article's level of scientific evidence, only ten were included for analysis. Eight studies were related to rehabilitations in the mandible and two were bi-maxillary. The analysis of the studies showed that complications and type of maintenance are primarily related to the loss of retention and the need to replace the nylon male component of the system. Patient's satisfaction was highlighted in five articles of this research. CONCLUSION: The overall satisfaction rates of patients seem to indicate this system as a viable clinical option of prosthetic rehabilitation. Overdentures with the Locator® system appear to hold a good retention, either in the upper or lower jaw, but require frequent maintenance visits, due to complications observed in these prosthodontic rehabilitations.
AB - OBJECTIVE: To evaluate the success rate, complications, maintenance and patient satisfaction with implant-supported overdentures with the Locator® system, by means of a systematic review. MATERIALS AND METHODS: PICO approach was used to formulate the clinical question. Research was conducted in primary (PubMed® and B-On®) and secondary (Cochrane®) information sources using different logical combination strategies of text words and MESH terms. Articles were selected according to research theme and scientific level evidence. RESULTS: 55 articles were found. After reading the title and summary, and evaluating the article's level of scientific evidence, only ten were included for analysis. Eight studies were related to rehabilitations in the mandible and two were bi-maxillary. The analysis of the studies showed that complications and type of maintenance are primarily related to the loss of retention and the need to replace the nylon male component of the system. Patient's satisfaction was highlighted in five articles of this research. CONCLUSION: The overall satisfaction rates of patients seem to indicate this system as a viable clinical option of prosthetic rehabilitation. Overdentures with the Locator® system appear to hold a good retention, either in the upper or lower jaw, but require frequent maintenance visits, due to complications observed in these prosthodontic rehabilitations.
UR - http://www.scopus.com/inward/record.url?scp=85058516664&partnerID=8YFLogxK
M3 - Article
C2 - 29806650
AN - SCOPUS:85058516664
SN - 1392-8589
VL - 19
SP - 124
EP - 129
JO - Stomatologija
JF - Stomatologija
IS - 4
ER -