TY - JOUR
T1 - Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit
AU - Ferreira, Alexandra M.R.
AU - Lima, José L.F.C.
AU - Rangel, António O.S.S.
PY - 1996
Y1 - 1996
N2 - A flow injection analysis (FIA) system incorporating a gas- diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas- permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2- ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always <5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation <3%).
AB - A flow injection analysis (FIA) system incorporating a gas- diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas- permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2- ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always <5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation <3%).
KW - Ammonium ion-selective electrode
UR - http://www.scopus.com/inward/record.url?scp=0029663283&partnerID=8YFLogxK
U2 - 10.1071/SR9960503
DO - 10.1071/SR9960503
M3 - Article
AN - SCOPUS:0029663283
SN - 0004-9573
VL - 34
SP - 503
EP - 510
JO - Australian Journal of Soil Research
JF - Australian Journal of Soil Research
IS - 4
ER -