TY - JOUR
T1 - Validation of an LC-MS/MS method for the quantification of caffeine and theobromine using non-matched matrix calibration curve
AU - Mendes, Vera M.
AU - Coelho, Margarida
AU - Tomé, Angelo R.
AU - Cunha, Rodrigo A.
AU - Manadas, Bruno
N1 - Funding Information:
Funding: This work was financed by the European Regional Development Fund (ERDF) through the COMPETE 2020—Operational Programme for Competitiveness and Internationalisation and Portuguese national funds via FCT—Fundação para a Ciência e a Tecnologia, I.P., under projects: PTDC/NEU-NMC/0205/2012, POCI-01-0145-FEDER-007440 (ref.; UID/NEU/04539/2019), POCI-01-0145-FEDER-016428 (ref.: SAICTPAC/0010/2015), POCI-01-0145-FEDER-016795 (ref.: PTDC/NEU-SCC/7051/2014), POCI-01-0145-FEDER-029311 (ref.: PTDC/BTM-TEC/29311/2017), POCI-01-0145-FEDER-30943 (ref.: PTDC/MEC-PSQ/30943/2017) and PTDC/MED-NEU/27946/2017; and by The National Mass Spectrometry Network (RNEM) under the contract POCI-01-0145-FEDER-402-022125 (ref.: ROTEIRO/0028/2013). MC was supported by PhD fellowship PD/BD/135178/2017, co-financed by the European Social Fund (ESF) through the POCH - Programa Operacional do Capital Humano and national funds via FCT.
Publisher Copyright:
© 2019 by the authors.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2019/8/7
Y1 - 2019/8/7
N2 - Caffeine is one of the most widely consumed psycho-stimulants. The study of the beneficial effects of caffeine consumption to decrease the risk of developing several neuropsychiatric pathologies is receiving increasing attention. Thus, accurate and sensitive methods have been developed, mainly by LC-MS/MS, in order to quantify caffeine and its metabolites. These quantifications of caffeine and its metabolites by LC-MS/MS require a considerable effort to select or find a surrogate matrix, without the compounds of interest, to be used in the calibration curves. Thus, we evaluated the possibility of using calibration curves prepared in solvent instead of calibration curves prepared in human plasma. Results show that the calibration curves prepared in solvent and in human plasma were similar by comparing their slopes and interceptions, and the accuracy and precision were within the limits of acceptance for both calibration curves. This work demonstrates that, by using internal standards, it is possible to use a calibration curve in solvent instead of a calibration curve in plasma to perform an accurate and precise quantification of caffeine and theobromine.
AB - Caffeine is one of the most widely consumed psycho-stimulants. The study of the beneficial effects of caffeine consumption to decrease the risk of developing several neuropsychiatric pathologies is receiving increasing attention. Thus, accurate and sensitive methods have been developed, mainly by LC-MS/MS, in order to quantify caffeine and its metabolites. These quantifications of caffeine and its metabolites by LC-MS/MS require a considerable effort to select or find a surrogate matrix, without the compounds of interest, to be used in the calibration curves. Thus, we evaluated the possibility of using calibration curves prepared in solvent instead of calibration curves prepared in human plasma. Results show that the calibration curves prepared in solvent and in human plasma were similar by comparing their slopes and interceptions, and the accuracy and precision were within the limits of acceptance for both calibration curves. This work demonstrates that, by using internal standards, it is possible to use a calibration curve in solvent instead of a calibration curve in plasma to perform an accurate and precise quantification of caffeine and theobromine.
KW - Caffeine
KW - LC-MS/MS
KW - Non-matched matrix calibration curve
UR - http://www.scopus.com/inward/record.url?scp=85070695102&partnerID=8YFLogxK
U2 - 10.3390/molecules24162863
DO - 10.3390/molecules24162863
M3 - Article
C2 - 31394755
AN - SCOPUS:85070695102
SN - 1420-3049
VL - 24
JO - Molecules
JF - Molecules
IS - 16
M1 - 2863
ER -