Avançar para navegação principal Avançar para pesquisar Avançar para conteúdo principal

Critical evaluation of restrictions used to optimize sterization processing conditions

Resultado de pesquisa

31 Transferências (Pure)

Resumo

A computer program, using a finite differences method, was developed to model the heat sterilization for cylindrical packaged conduction heating foods. This program was introduced into an optimization routine to calculate optimum processing conditions, maximizing the surface or the volume average quality, using different restrictions. Depending on the pack dimensions and the heating rate of the product the least-lethality point is at the geometric center or along the radius or the vertical axis. Therefore, sterility values specified at the center and at the least-Iethality point were used as sterility criteria for calculating optimum conditions. The effect of an integrated sterility value constraint on optimal temperature was also investigated. Depending on the product thermal properties, processing conditions and target lethality the optimum temperature calculated using the sterility value at the center as restriction can overestimate the correct value by as much as 4°C.
Idioma originalEnglish
Número de páginas8
Estado da publicaçãoPublicado - 1994
Evento4th Bath Food Process Engineering Conference - Bath
Duração: 19 set. 199421 set. 1994

Conferência

Conferência4th Bath Food Process Engineering Conference
País/TerritórioUnited Kingdom
CidadeBath
Período19/09/9421/09/94

Impressão digital

Mergulhe nos tópicos de investigação de “Critical evaluation of restrictions used to optimize sterization processing conditions“. Em conjunto formam uma impressão digital única.

Citação