Resumo
This study examines stress analysis of the mandible when submitted to mastication simulated forces over a distal extension removable partial denture. Two situations were analyzed upon loading: small pins had been placed over the bone crest and under the denture; low amplitude loads were applied over tooth 34-37. Holographic interferometry techniques were used to assess mandible's deformation. Results indicate that a correct adaptation of the denture base is critical to reduce stresses in the mandible. High stress levels in the second molar region suggest its non-inclusion in these prosthetic rehabilitations.
| Idioma original | English |
|---|---|
| Páginas (de-até) | 111-115 |
| Número de páginas | 5 |
| Revista | European Journal of Prosthodontics and Restorative Dentistry |
| Volume | 17 |
| Número de emissão | 3 |
| Estado da publicação | Publicado - set. 2009 |