Avançar para navegação principal Avançar para pesquisar Avançar para conteúdo principal

Holographic stress analysis in a distal extension removable partial denture.

  • José Carlos Reis Campos*
  • , André Correia
  • , Mário Augusto Pires Vaz
  • , Fernando Jorge Morais Branco
  • *Autor correspondente para este trabalho

Resultado de pesquisarevisão de pares

5 Citações (Scopus)

Resumo

This study examines stress analysis of the mandible when submitted to mastication simulated forces over a distal extension removable partial denture. Two situations were analyzed upon loading: small pins had been placed over the bone crest and under the denture; low amplitude loads were applied over tooth 34-37. Holographic interferometry techniques were used to assess mandible's deformation. Results indicate that a correct adaptation of the denture base is critical to reduce stresses in the mandible. High stress levels in the second molar region suggest its non-inclusion in these prosthetic rehabilitations.
Idioma originalEnglish
Páginas (de-até)111-115
Número de páginas5
RevistaEuropean Journal of Prosthodontics and Restorative Dentistry
Volume17
Número de emissão3
Estado da publicaçãoPublicado - set. 2009
Publicado externamenteSim

Impressão digital

Mergulhe nos tópicos de investigação de “Holographic stress analysis in a distal extension removable partial denture.“. Em conjunto formam uma impressão digital única.

Citação