Avançar para navegação principal Avançar para pesquisar Avançar para conteúdo principal

Use of rapid cardiac magnetic resonance imaging to guide chelation therapy in patients with transfusion-dependent thalassaemia in India: UMIMI study

  • Katia Menacho Medina
  • , Amna Abdel-Gadir
  • , Kartik Ganga
  • , Vineeta Ojha
  • , Surya Pratap
  • , Redha Boubertakh
  • , Louise McGrath
  • , João B. Augusto
  • , Alexander Rikowski
  • , Nabila Mughal
  • , Virender Kumar Khanna
  • , Tulika Seth
  • , Sanjiv Sharma
  • , Amita Mahajan
  • , Rajiv K. Bansal
  • , Prabhar Srivastava
  • , Harsh Mahajan
  • , Vidhur Mahajan
  • , Judith Walker
  • , Tenzin Seldon
  • Emmanuel Ako, James C. Moon, John Malcolm Walker

Resultado de pesquisarevisão de pares

1 Citação (Scopus)

Resumo

AIMS: To explore the impact of incorporating a faster cardiac magnetic resonance (CMR) imaging protocol in a low-middle-income country (LMIC) and using the result to guide chelation in transfusion-dependent patients. METHODS AND RESULTS: A prospective UK-India collaborative cohort study was conducted in two cities in India. Two visits 13 months apart included clinical assessment and chelation therapy recommendations based on rapid CMR results. Participants were recruited by the local patient advocate charity, who organized the patient medical camps. The average scanning time was 11.3 ± 2.5 min at the baseline and 9.8 ± 2.4 min (P < 0.001) at follow-up. The baseline visit was attended by 103 patients (mean age 25 years) and 83% attended the second assessment. At baseline, 29% had a cardiac T2* < 20 ms, which represents significant iron loading, and 12% had left ventricular ejection fraction <60%, the accepted lower limit in this population. Only 3% were free of liver iron (T2* ≥ 17 ms). At 13 months, more patients were taking intensified dual chelation therapy (43% vs. 55%, P = 0.002). In those with cardiac siderosis (baseline T2* < 20 ms), there was an improvement in T2*-10.9 ± 5.9 to 13.5 ± 8.7 ms, P = 0.005-and fewer were classified as having clinically important cardiac iron loading (T2* < 20 ms, 24% vs. 16%, P < 0.001). This is the first illustration in an LMIC that incorporating CMR results into patient management plans can improve cardiac iron loading. CONCLUSION: For thalassaemia patients in an LMIC, a simplified CMR protocol linked to therapeutic recommendation via the patient camp model led to enhanced chelation therapy and a reduction in cardiac iron in 1 year.

Idioma originalEnglish
Páginas (de-até)289-297
Número de páginas9
RevistaEuropean heart journal. Quality of care & clinical outcomes
Volume8
Número de emissão3
DOIs
Estado da publicaçãoPublicado - 5 mai. 2022
Publicado externamenteSim

ODS da ONU

Este resultado contribui para o(s) seguinte(s) Objetivo(s) de Desenvolvimento Sustentável

  1. ODS 3 - Boa saúde e bem-estar
    ODS 3 Boa saúde e bem-estar

Impressão digital

Mergulhe nos tópicos de investigação de “Use of rapid cardiac magnetic resonance imaging to guide chelation therapy in patients with transfusion-dependent thalassaemia in India: UMIMI study“. Em conjunto formam uma impressão digital única.

Citação